Please use this identifier to cite or link to this item: http://monografias.ufrn.br/handle/123456789/3250
Title: Avaliação do Estado Funcional do Paciente Internado e Correlação entre Instrumentos de Avaliação Funcional
Other Titles: Assessment of the Functional Status of the Hospitalized Patient and Correlation Between Functional Instruments
Authors: Santos, Juliana Simonelly Felix dos
Keywords: internação hospitalar;imobilismo;capacidade funcional
Issue Date: 1-Dec-2016
Publisher: Universidade Federal do Rio Grande do Norte
Citation: SANTOS, Juliana Simonelly Felix dos. Avaliação do Estado Funcional do Paciente Internado e Correlação entre Instrumentos de Avaliação Funcional. 2016. 28 f. Trabalho de Conclusão de Curso (Bacharelado) - Curso de Fisioterapia, Universidade Federal do Rio Grande do Norte - UFRN, Santa Cruz, 2016.
Portuguese Abstract: A internação hospitalar provoca restrição ao leito nos pacientes submetidos a esta condição. Os déficits envolvem o sistema osteomioarticular e cardiorrespiratório, interferindo na funcionalidade e força dos internados. O objetivo desse estudo foi avaliar o estado funcional de pacientes internados no setor de clínica médica e estabelecer correlação entre diferentes instrumentos de avaliação. Trata-se de um estudo transversal, realizado no Hospital Regional Dr. Mariano Coelho, Currais Novos/RN. As escalas utilizadas para avaliação da funcionalidade e força muscular foram: Functional Status Scale (FSS), Medida de Independência Funcional (MIF) e Physical Function ICU Test (PFIT) e Medical Research Council (MRC). As variáveis foram analisadas segundo média, desvio padrão e frequências e teste de normalidade pelo Kolmogorov-Smirnov, correlação entre variáveis pelo teste de Pearson, segundo Graphpad Prism 5.0 com significância de p<0,05. Participaram 24 pacientes, 14 homens (58,3%) e 10 mulheres (41,6%), com idade média de 63,1 (±8,9) anos e tempo de internação de 4,6 (±2,6) dias. Houve déficit funcional em todas escalas, exceto na MIF apresentando médias de independência para todos domínios. Houve correlação positiva e forte entre MRC, FSS, PFIT e MIF (r=0,74; r=0,88; r=0,71) p<0,0001 e entre as escalas de funcionalidade FSS, PFIT e MIF (r=0,85; r=0,82; r=0,81) p<0,0001, respectivamente. Entre a PFIT e tempo de internação houve correlação negativa e moderada (r=-0,41), p=0,046, as demais não apresentaram correlação. A internação hospitalar teve impacto na funcionalidade e força dos internados. Os instrumentos mostraram correlação entre si e sensibilidade para identificar comprometimentos, contribuindo para elaboração de intervenções preventivas para essas alterações.
Abstract: Hospitalization causes restriction in patients submitted to this condition. Deficits involve the osteomioarticular and cardiorespiratory systems, interfering with the functionality and strength of these patients. The aim of this study was to evaluate the functional status of hospitalized patients in the medical clinic sector and to establish a correlation between different assessment instruments. It is a cross-sectional study, performed at the Regional Dr. Mariano Coelho Hospital, Currais Novos/RN. Functional Status Scale (FSS), Functional Independence Measure (MIF), and Physical Function ICU Test (PFIT) and Medical Research Council (MRC) were used to evaluate functional and muscular strength. The variables were analyzed according to mean, standard deviation and frequencies, in addition to normality test by Kolmogorov-Smirnov and correlation between variables by the Pearson test, according to Graphpad Prism 5.0 with significance level of p<0.05. Twenty-four patients (58.3%) and 10 women (41.6%) had a mean age of 63.1 (±8.9) years and a mean length of hospitalization of 4.6 (±2.6) days. There was functional deficit in all scales, except in the MIF, presenting independence means for both domains. There was a positive and strong correlation between MRC, FSS, PFIT and MIF (r=0.74, r=0.88, r=0.71) p<0.0001 and between the FSS, PFIT and MIF r=0.85, r=0.82, r=0.81), p<0.0001, respectively. Between the PFIT and hospitalization time there was a negative and moderate correlation (r=-0.41), p=0.046, the others did not present a correlation. Hospitalization had an impact on the functionality and strength of these patients. The instruments showed a correlation between themselves and sensitivity for the identification of impairments, contributing to the elaboration of preventive interventions for these alterations.
URI: http://monografias.ufrn.br/jspui/handle/123456789/3250
Other Identifiers: 2012963795
metadata.dc.description.embargo: 2019-12-15
Appears in Collections:Fisioterapia

Files in This Item:
File Description SizeFormat 
Avaliação do Estado Funcional do Paciente Internado e Correlação entre Instrumentos de Avaliação Funcional.pdf
Restricted Access Until 2019-12-14
TCC Avaliação do Estado Funcional do Paciente Internado e Correlação entre Instrumentos de Avaliação Funcional540,46 kBAdobe PDFView/Open    Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.